1 888 509 8455 | clientservice@integrys.com

Discount Products: Look through products available for a 25% – 50% discount in 2020. The items provided on a first come, first serve basis.
View Discounted Products

Uncategorized


    • 2 x Redundant MIL-STD-1553 Channels
    • 8 x ARINC-429/575 Tx/Rx Channels
    • 8 x RS-232/422/485 Sync/Async Serial Channels
    • 28 VDC Input PSU with 50 ms holdup option

    • 2 x Redundant MIL-STD-1553 Channels
    • 8 x ARINC-429/575 Tx/Rx Channels
    • 8 x RS-232/422/485 Sync/Async Serial Channels
    • 28 VDC Input PSU with 50 ms holdup option

     

  • with 10 GB Fiber Optic & 1 GB Copper Ethernet Switch

    • Preconfigured embedded I/O Functions: 24-CH Discrete I/O, 8-CH ARINC 429/575, 4-CH CANBus (programmable for CAN 2.0A/B, ARINC 825 or CAN FD protocol) and 2-CH MIL-STD-1553
    • Ethernet switch module that offers four (4) 10GBase-SR multimode fiber optic ports and sixteen (16) 10/100/1000Base-T Ethernet ports
    • Supports One NAI smart I/O function module
    • Minimized SWaP Footprint
    • Xilinx UltraScale+ SoC with Dual/Quad Core ARM Cortex®-A53 processors
    • 28 VDC Input Power Supply (50+ ms Hold-up Option)
    • DO-178C & DO-254 DAL A (Contact Factory)
    • Cybersecurity & Anti-Tamper (Contact Factory)

     

    • Intel “Apollo Lake” x5-E3940 1.6GHz (burstable 1.8GHz) quad-core processor with 15-year lifecycle
    • 4GB non-ECC or 8GB ECC RAM soldered down
    • Integrated professional-quality analog and digital data acquisition subsystem with software support
    • Bottom side heat spreader with integrated thermal pad provides efficient cooling and convenient mounting
    • Full -40 to +85ºC industrial operating temperature range
    • Thicker PCB and latching connectors increase resistance to shock and vibration
    • PCIe/104 OneBank expansion socket for industry-standard rugged I/O expansion
    • Minicard expansion socket for versatile low-cost I/O

     

  • 6x 3U OpenVPX MOSA Remote Interface Unit

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x RS-232/422/485 Serial Channels (SC3)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 8 x Programmable RTD or Thermocouple measurement (TR1)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 8 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 2 x AC Reference Excitation (AC2)
    • 4 x Strain Gage Measurement (SG1)
    • 8 x Variable Reluctance/Pulse Counter Measurement Channels (VR1)
    • 16 x 10/100/100 Base-T Ethernet Switch (ES2)
    • 48 x Discrete Input Channels and 48 Programmable Discrete I/O Channels (68DT1)
    • 28 VDC MIL-STD-704 Aircraft Electrical Power Characteristics with at least 50 ms holdup.
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 4x 3U OpenVPX MOSA Remote Interface Unit

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x RS-232/422/485 Serial Channels (SC3)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 8 x Programmable RTD or Thermocouple measurement (TR1)
    • 8 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 2 x AC Reference Excitation (AC2)
    • 4 x Strain Gage Measurement (SG1)
    • 8 x Variable Reluctance/Pulse Counter Measurement Channels (VR1)
    • 48 x Discrete Input Channels and 48 Programmable Discrete I/O Channels (68DT1)
    • 28 VDC MIL-STD-704 Aircraft Electrical Power Characteristics with at least 50 ms holdup.
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 6x 3U OpenVPX MOSA Mission Computer

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x RS-232/422/485 Serial Channels (SC3)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 4 x MIL-STD-1553/1760 (2 x FTJ)
    • 4 x Non-Latching Relay (RY1)
    • 24 x Enhanced Programmable Discrete I/O Channels (DT4)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 12 x ±10 VDC or ±25 mA D/A Outputs (DA1)
    • 12 x ±1.25 to ±10.0 A/D Channels (AD1)
    • 12 x ±100V A/D Channels (AD2)
    • 16 x ±1.25 to ±10.0 VDC A/D Channels (AD4)
    • 16 x 10/100/100 Base-T Ethernet Switch (ES2)
    • 48 x Discrete Input Channels and 48 Programmable Discrete I/O Channels (68DT1)
    • 28 VDC Input PSU per VITA 62 (VPX68) Optional 50 ms holdup.
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 4x 3U OpenVPX MOSA Mission Computer

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x RS-232/422/485 Serial Channels (SC3)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 24 x Enhanced Programmable Discrete I/O Channels (DT4)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 12 x ±10 VDC or ±25 mA D/A Outputs (DA1)
    • 16 x 10/100/100 Base-T Ethernet Switch (ES2)
    • 48 x Discrete Input Channels and 48 Programmable Discrete I/O Channels (68DT1)
    • 28 VDC Input PSU per VITA 62 (VPX68) with Optional 50 ms holdup.
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 2x 3U OpenVPX MOSA Mission Computer

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x RS-232/422/485 Serial Channels (SC3)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 24 x Enhanced Programmable Discrete I/O Channels (DT4)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 12 x ±10 VDC or ±25 mA D/A Outputs (DA1)
    • 28 VDC Input PSU per VITA 62 (VPX68). Optional 50 ms holdup.
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 4x 3U OpenVPX MOSA Flight Control Computer

    • 8 x ARINC-429 Tx/Rx & 12 Programmable Discrete IO (CM2)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 8 x Programmable RS-232/422/485 Serial Channels (SC3)
    • 2 x AC Excitation References (AC2)
    • 4 x LVDT Measurement Channels (LD2)
    • 4 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 28 VDC Input PSU per VITA 62 (VPX68) with at least 50 ms holdup
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 2x 3U OpenVPX MOSA Flight Control Computer

    • 8 x ARINC-429 Tx/Rx & 12 Programmable Discrete IO (CM2)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 8 x Programmable RS-232/422/485 Serial Channels (SC3)
    • 2 x AC Excitation References (AC2)
    • 4 x LVDT Measurement Channels (LD2)
    • 4 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 28 VDC Input PSU per VITA 62 (VPX68) with at least 50 ms holdup
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 6x 3U OpenVPX MOSA Data Concentrator Unit

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 8 x RS-232/422/485 Serial Channels (SC3)
    • 2 x AC Excitation References (AC2)
    • 4 x LVDT Measurement Channels (LD2)
    • 8 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 8 x Variable Reluctance/Pulse Counter Measurement Channels (VR1)
    • 6 x Chip Detect and Fuzz Burn Channels (CD1)
    • 4 x Strain Gage Measurement (SG1)
    • 12 x ±10 VDC or ±25 mA D/A Outputs (DA1)
    • 16 x Enhanced Differential Discrete I/O Channels (DF2)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 16 x Programmable RTD or Thermocouple measurement (2 x TR1)
    • 12 x ±10 VDC or ±25 mA D/A Outputs (DA1)
    • 48 x Discrete Input Channels and 48 Programmable Discrete I/O Channels (68DT1)
    • 28 VDC Input PSU per VITA 62 (VPX68) with at least 50 ms holdup
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 2x 3U OpenVPX MOSA Data Concentrator Unit

    • 2 x MIL-STD-1553 & 8 x ARINC-429 Tx/Rx (CM5)
    • 8 x Programmable RS-232/422/485 Serial Channels (SC3)
    • 8 x CANBus A/B 2.0/CAN-FD/ARINC-825 (CB8)
    • 8 x Variable Reluctance/Pulse Counter Measurement Channels (VR1)
    • 6 x Chip Detect and Fuzz Burn Channels (CD1)
    • 4 x Strain Gage Measurement (SG1)
    • 28 VDC Input PSU per VITA 62 (VPX68) with at least 50 ms holdup
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 4x 3U OpenVPX MOSA Actuator Interface Unit

    • 2 x MIL-STD-1553 & 12 x Programmable Discrete IO (CM8)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 8 x Programmable RS-232/422/485 Serial Channels (SC3)
    • 2 x AC Excitation References (AC2)
    • 4 x LVDT Measurement Channels (LD2)
    • 4 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 24 x ARINC-429/575 Channels (2 x AR1)
    • 16 x Programmable RTD or Thermocouple measurement (2 x TR1)
    • 16 x Variable Reluctance/Pulse Counter Measurement Channels (VR1)
    • 28 VDC Input PSU per VITA 62 (VPX68) with at least 50 ms holdup.
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 2x 3U OpenVPX MOSA Actuator Interface Unit

    • 2 x MIL-STD-1553 & 12 x Programmable Discrete IO (CM8)
    • 16 x ±100 VDC A/D Channels (ADF)
    • 8 x Programmable RS-232/422/485 Serial Channels (SC3)
    • 2 x AC Excitation References (AC2)
    • 4 x LVDT Measurement Channels (LD2)
    • 4 x ±40 VDC 100 mA Digital to Analog Channels (DA3)
    • 28 VDC Input PSU per VITA 62 (VPX68) with at least 50 ms holdup
    • MIL-STD-810G, MIL-STD-461F and DO-160 environmental and EMI/EMC qualifications.

     

  • 1-2 Independent, Dual Redundant 1553 Channels on Small Mezzanine

    • 1-2 Independent, Dual Redundant 1553 Channels on Small Mezzanine
    • 10/100/1000 Ethernet Interface
    • Reference-Development Card Available
    • Full Schematics, Design Guidelines, ESS Test Examples, and 3-D STEP Files
    • Dual Function (BC/Mon or mRT/Mon) or
      Full Function (BC/mRT/Mon)
    • One Mbyte of Memory per Channel
    • Fully Compliant to MIL-STD-1553B/C Notice II/IV,1553A and Link-16
    • Commercial or Industrial Extended Temperature Parts
    • A/D Signal Capture for Cable Troubleshooting and Cybersecurity Modeling. First Channel Only
    • MIL-1760 Ext RT Addressing First Channel
    • True HW Playback – HW Sync Channels
    • Industry First: 20ns Signal Generation
    • IRIG-B RX PAM or RX/TX PPS Ext Clock
    • AltaAPI SDK Provided. Use the Exact Same Code as Other Alta Products.
    • Auto Ethernet Bridging for Bus Monitor! No Programming Needed.
    • Wireshark Dissectors – Decode Auto UDP BM Messages in Wireshark!
      • 100% or Filtered Subaddress Messages
    • Advanced BIT Features and Dual Temperature Sensor

     


Filters

 