1 888 509 8455 | clientservice@integrys.com

FLIR A615 Series Thermal Imaging Cameras

0 out of 5
  • Automatic, based on inputs for distance, atmospheric temperature and relative humidity
  • Automatic, based on signals from internal sensors
  • Variable from 0.01 to 1.0
  • Automatic, based on input of reflected temperature
  • Automatic, based on input of optics/window transmission and temperature
  • Global object parameters
  • TCP/IP socket-based FLIR proprietary and GenICam protocol

 

SKU: 55001-0101. Categories: , , .
Request a Quote

Description

The FLIR  A615 is a series of compact and affordable thermal imaging cameras, fully controlled by a PC. Due to their compliance to standards,  A615 are Plug&Play with third-party Machine Vision software like National instruments, Cognex, Matrox, MVtec and Stemmer Imaging.

Camera specific

Imaging & Optical Data FLIR A615
Field of view (FOV) / Minimum focus distance 15°: 15° × 11° (19° diagonal) / 0.50 m (1.64 ft.) 25°: 25° × 19° (31° diagonal) / 0.25 m (0.82 ft.) 45°: 45° × 34° (55° diagonal) / 0.15 m (0.49 ft.) 7°: 7° × 5.3° (8.7° diagonally) / 2.0 m (6.6 ft.) 80°: 80° × 64.4° (92.8° diagonal) / 65 mm (2.6 in.)
Spatial resolution (IFOV) 15°: 0.41 mrad 25°: 0.68 mrad 45°: 1.23 mrad 7°: 0.19 mrad 80°: 2.62 mrad
Focal length 15°: 41.3 mm (1.63 in.) 25°: 24.6 mm (0.97 in.) 45°: 13.1 mm (0.52 in.) 7°: 88.9 mm (3.5 in.) 80°: 6.5 mm (0.26 in.)
F-number 1.0
Image frequency 50 Hz (100/200 Hz with windowing)
Detector data
Focal Plane Array (FPA) / Spectral range Uncooled microbolometer / 7.5–14 μm
IR resolution 640 × 480 pixels
Detector pitch 17 μm
Detector time constant Typical 8 ms
Measurement
Object temperature range -20 to +150°C +100 to +650°C +300 to +2000°C
USB
USB Control and image
USB, standard USB 2 HS
USB, connector type USB Mini-B
USB, communication TCP/IP socket-based FLIR proprietary
USB, image streaming 16-bit 640 × 480
pixels at 25 Hz
– Signal linear
– Temperature linear
– Radiometric
USB, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet
Ethernet, image streaming 16-bit 640 × 480
pixels at 50 Hz
16-bit 640 × 240
pixels at 100 Hz
16-bit 640 × 120
pixels at 200 Hz
– Signal linear
– Temperature linear
– Radiometric
GigE Vision and GenICam compatible
Imaging & Optical Data
Lens identification Automatic
Thermal sensitivity/NETD < 0.05°C @ +30°C (86°F) / 50 mK
Focus Automatic or manual (built in motor)
Measurement
Accuracy ±2°C or ±2% of reading
Measurement analysis
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correction Automatic, based on signals from internal sensors
Emissivity correction Variable from 0.01 to 1.0
Reflected apparent temperature correction Automatic, based on input of reflected temperature
External optics/windows correction Automatic, based on input of optics/window transmission and temperature
Measurement corrections Global object parameters
Ethernet
Ethernet Control and image
Ethernet, standard IEEE 802.3
Ethernet, connector type RJ-45
Ethernet, type Gigabit Ethernet
Ethernet, communication TCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, protocols TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Digital input/output
Digital input 2 opto-isolated, 10–30 VDC
Digital output, purpose Output to ext. device (programmatically set)
Digital output 2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage 500 VRMS
Digital I/O, supply voltage 12/24 VDC, max 200 mA
Digital I/O, connector type 6-pole jackable screw terminal
Digital input, purpose Image tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
Power system
External power operation 12/24 VDC, 24 W absolute max
External power, connector type 2-pole jackable screw terminal
Voltage Allowed range 10–30 VDC
Environmental data
Storage temperature range –40°C to +70°C (-40 to 158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (77 to 104°F)
EMC • EN 61000-6-2:2001 (Immunity) • EN 61000-6-3:2001 (Emission) • FCC 47 CFR Part 15 Class B (Emission)
Vibration 2 g (IEC 60068-2-6)
Physical data
Housing material Aluminium
Scope of delivery
Hard transport case or cardboard box, Thermal imaging camera with lens, Utility CD-ROM, Calibration certificate, Ethernet™ cable, USB cable (FLIR A615), Mains cable, Power cable (pig-tailed), Power supply, Printed Getting Started Guide, Printed Important Information Guide, User documentation CD-ROM, Warranty extension card or Registration card, 6-pole screw terminal (mounted on camera)

 

Reviews

There are no reviews yet!

Be the first to write a review

*

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Download Data Sheet
Download Data Sheet 2
Download Data Sheet 3
Delivery and Returns Content description.

Contact Integrys

Address

3585 Laird Road, Unit 15 & 16,
Mississauga ON L5L 5Z8

Phone:

Local Phone: 905-502-2070
Toll Free: 888-509-8455
Local Fax: 905-890-1959
Toll Free Fax: 888-509-8456

Email:

info@integrys.com

About Integrys

For more than 50 years, Integrys has been the industry leader in selecting and evaluating new embedded, high-availability computer, imaging and video technology and engineering solutions for demanding markets and applications. The Integrys “seal of approval” is your assurance of proven value. These solutions include not only COTS products, but associated support and engineering services of value to our customers.

Integrys Location

Smartform